Evaluation of Stator and Rotor Interturn Stress with Electrical Signature Analysis in Variable Frequency Drive and Wind Generator Applications

Abstract— Electrical Signature Analysis is the application and analysis of Voltage and Current data collected on electrical machinery systems.  The measurements are converted to amplitude modulated Fast Fourier Transforms that can be evaluated for power, machine and powertrain conditions.  Electrical and mechanical conditions are determined through their effects on the airgap magnetic field.  One of…

Evaluating Direct-Current Motors Using Motor Circuit Analysis Basics

Howard W Penrose, Ph.D., CMRP MotorDoc LLC, www.motordoc.com The term MCA (Motor Circuit Analysis) is derived from a test method that provides information on the basic components of an alternate-current (AC) or direct-current (DC) electric motor. These basic components include: resistance, measured in Ohms; impedance, measured in Ohms; inductance, measured in Henries; the induction winding…

Evaluation of Offline Partial Discharge in Vacuum Environments

An evaluation of several insulation types at various degrees of vacuum using repetitive discharge inception and extinction voltage offline testing will be presented.  Insulation systems were evaluated in atmosphere and compared to values to 1mmHg using a commercial partial discharge surge tester.  The insulation systems evaluated include unvarnished windings, dip and bake epoxy, epoxy trickle…